CAN Relay Box

1.​047.3xx.xxE (choose order option)

The CAN Relay Box is the appropriate product when you want to determine potential-free, switching output signals that must be connected. You can set the signal potential yourself and individually for your application. The 12 potential-free relays can be activated using CAN messages. The module can be integrated into your network as a separate PLC or as a simple I/O module.

The box is very compact and thus space-saving, but still very versatile because relays and control functions are integrated into one device. This reduces the wiring outlay in your application.

NameValue
Dimensions 89 × 95 × 35 mm
Housing material Plastics
Connector type 3x 18-poliger Molex Mini Fit Junior
In-/Outputs (total) 25
Operating voltage 9-30 V
Protection class IP53
NameValue
Number of pins 54
In-/Outputs (total) 25
Inputs (total) 13
Inputs (analog) 13
Outputs (total) 12
Relay outputs 12
Processor family Freescale HCS08
Processor 8 bit
CAN interfaces 1
Temperature range -40 to 85 °C
Protection class IP53
Operating voltage 9-30 V
Current consumption (≤) 1 A
External overcurrent protection 1 A
Quiescent current (24V) 500 µA
Quiescent current (12V) 210 µA
Programming system MRS Developers Studio
performance per relay 4 A permanent load
Name Model Order no.
CAN Relay Box HS High-Speed 1.047.300.00E
CAN Relay Box LS Low-Speed 1.047.310.00E
Required accessoriesArticle number
Softwaretool MRS Developers Studio Bund­le 1.​100.​100.​09
Starter Kit - CAN Relay Box HS 1.​100.​110.​24
PCAN-USB Interface 105358
Cable set to program CAN Gateway Module / CAN Relay Box 109639
Connector package CAN Gateway Module / CAN Relay Box 109637
Cable FLRY 2 x 0.50 mm² white/green SL20 113085

Is there a terminating resistor on the CAN relay box?

Yes, the DIP switch on the board must be set to ON for this.
For more information, please contact our support.

What is the quiescent current of the CAN relay box?

The quiescent current is:
12 V => 0.21 mA
24 V => 0.50 mA

Is the CAN relay box CAN wake-up capable?

Yes, the CAN wake-up functionality can be set via the DIP switches (R131 switch 1).
For further information please contact our support.


Manual Connected Controller