Frequency Monitor 24 V

1.026.21x.xxxE (choose order option)

The frequency monitor measures the input signal frequency applied to terminal 15 and energizes/deenergizes the output when the signal frequency exceeds/drops below the defined threshold frequency. The threshold frequency can be selected from the 10 - 1.000 Hz frequency range. In addition, combinations including custom delay times are possible. Please refer to the chapter housing and base plates for additional housing options.

NameValue
Dimensions 30 × 30 × 40 mm
Housing material Plastics
Type-approval number 05 8091
Type-approval UNECE R 10 Rev. 05
Number of pins 6
In-/Outputs (total) 2
Operating voltage 24 V
NameValue
Number of pins 6
In-/Outputs (total) 2
Inputs (total) 1
Inputs (digital) 1
Outputs (total) 1
Relay outputs 1
Processor family Texas Instruments MSP 430
Processor 16 bit
Temperature range -40 to 85 °C
Protection class IP53
Operating voltage 24 V
Quiescent current (24V) 250 µA
Programming system MRS Realizer
switching frequency customer specific
continuous current limit 10 A open / 15 A close
Name Type Model Connection diagram Order no.
Frequency Monitor 24 V A Individual frequency (see below) S1 1.​026.​211.​xxxE
Frequency Monitor 24 V B Individual frequency (see below) S2 1.​026.​212.​xxxE
Required accessoriesArticle number
Softwaretool MRS Realizer 1.​100.​000.​01
Hous­ing bracket 1.​017.​080.​00
Socket ST FL 9-pin 5 x 6.3 / 4 x 2.8 1.​017.​002.​00
Socket package watertight 40 mm 114265
Tab receptacle for latching 2,8 mm 0,5 – 1,0 mm² 105292
Tab receptacle for latching 6,3 mm 1,0 mm² 102355
Tab receptacle for latching 6,3 mm 1,5 – 2,5 mm² 103064

Can the frequency thresholds also be chosen freely?

Yes, that works. Please specify the desired frequency thresholds when ordering.