Micro PLC CAN 4 ANA

1.112.300.00E (choose order option)

The Micro PLC CAN 4 ANA offers many possible applications with one analog input and four I/Os, whose function can be individually defined. These I/Os can be used as four analog outputs for currents from 0 to 24 mA and voltages from 0 to 10 V. They can also be configured as analog inputs. Additionally, the controller provides the option to configure two of the four I/Os as frequency inputs.

NameValue
Weight 30.2 g
Dimensions 30 × 30 × 40 mm
Housing material Plastics
Connector type Flachstecker 6,3 mm, Flachstecker 2,8 mm
In-/Outputs (total) 5
Operating voltage 9-30 V
Protection class IP53
Type-approval number 04 7522
Type-approval E1 - ECE R10
Protocols CAN Interface 2.0 A/B ISO 11898-2, SAE J1939
NameValue
Number of pins 9
In-/Outputs (total) 5
I/Os 4
Inputs (total) 4
Inputs (digital) 4
Inputs (analog) 4
Outputs (total) 4
Processor family Freescale HSC08
Processor 8 bit
CAN interfaces 1
Temperature range -40 to 85 °C
Protection class IP53
Operating voltage 9-30 V
Current consumption (≤) 25 mA
Programming system MRS Developers Studio
Quiescent current 250 µA
Name Model Connection diagram Order no.
Micro PLC CAN 4 ANA 1.​112.​300.​00E
Micro PLC CAN 4 ANA CANopen S1 1.​112P.​300.​00E
Required accessoriesArticle number
Star­ter Kit - Micro PLC CAN 4 ANA 1.​100.​110.​43
Softwaretool MRS Developers Studio Bund­le 1.​100.​100.​09
Hous­ing bracket 1.​017.​080.​00
PCAN-USB Interface 105358
Cable set to programm Micro PLC CAN / PROP CAN 109446
Cable FLRY 2 x 0.50 mm² white/green SL20 113085
Socket package watertight 40 mm 114265
Socket ST FL 9-pin 5 x 6.3 / 4 x 2.8 1.​017.​002.​00
Tab receptacle for latching 2,8 mm 0,5 – 1,0 mm² 105292
Tab receptacle for latching 6,3 mm 1,0 mm² 102355
Tab receptacle for latching 6,3 mm 1,5 – 2,5 mm² 103064

How can the analog input be switched from voltage to current?

The DO_I_XX is responsible for this.
This not only switches between current and voltage output, but also the input function.
DO_I_X = 1 switches eg. enter the power input of AI_X.

Which minimum output voltage does the Micro PLC CAN 4 ANA provide?

The analog output does not completely go down to 0 V. There remains a minimum voltage of 120 mV at the output


Manual Connected Controller

Here you can find the download to the manual of connected controller. Please read the manual before using the product the first time.